Cab Floor Anti-Lock Brake System (ABS) Wiring Harness
TM 9-2320-363-34-1 · Chapter 4 — Electrical System Maintenance
REPLACEMENT
This task covers: a. Removal b. Cleaning c. Inspection d. Installation
Tools and Special Equipment:
Equipment Condition:
Shop Equipment, SC 4910-95-CL-A31
Reference Condition Description
Tool Kit, SC 5180-90-CL-N05
TM 9-2320-363-20 Batteries Disconnected
References:
TM 9-2320-363-20
NOTE
l Wiring harness and leads are secured in place by wire ties, cushion clamps, and
screw terminals.
l Only remove hardware securing harness or lead to be removed.
DISCONNECT AND REMOVE CAB FLOOR ABS WIRING HARNESS USING ILLUSTRATION AND
TABLE AS A GUIDE.
Use general cleaning methods to clean all parts (page 2-30).
Inspect all parts for wear or damage.
NOTE
l Wiring harness and leads are secured in place by wire ties, cushion clamps, and
screw terminals.
l Make sure harness is secure and all hardware is tight.
INSTALL AND CONNECT CAB FLOOR WIRING HARNESS USING ILLUSTRATION AND TABLE
AS A GUIDE.
NOTE
Follow-on Maintenance:
Connect batteries (TM 9-2320-363-20).
TM page Change 1 4-39
QTY TABLE
1 4-Pin Female Connector 1 2 3-Pin Female Connector 1 3 1-Pin Female Connector 1
TM page 4-39.0 Change 1
REPLACEMENT (CONT)
ALL EXCEPT M915A2 AND M916A1
TABLE QTY
1 4-Pin Male Connector 2 2 6-Pin Male Connector 2 3 6-Pin Female Connector 1 4 6-Pin Female Connector 1
TM page Change 1 4-39.1
THIS PAGE INTENTIONALLY LEFT BLANK
TM page 4-40